Using Mellanox ConnectX VPI Ports to Ethernet or InfiniBand

The Mellanox ConnectX5 VPI adapter supports both Ethernet and InfiniBand port modes, which must be configured.

Check Status

# mst status -v
MST modules:
------------
    MST PCI module is not loaded
    MST PCI configuration module is not loaded
PCI devices:
------------
DEVICE_TYPE             MST                           PCI       RDMA            NET                                     NUMA  
ConnectX4(rev:0)        /dev/mst/mt4115_pciconf3      8b:00.0   mlx5_3                                                  1     

ConnectX4(rev:0)        /dev/mst/mt4115_pciconf2      84:00.0   mlx5_2                                                  1     

ConnectX4(rev:0)        /dev/mst/mt4115_pciconf1      0c:00.0   mlx5_1                                                  0     

ConnectX4(rev:0)        /dev/mst/mt4115_pciconf0      05:00.0   mlx5_0                                                  0                                                 1    

Start MST

# mst start
Starting MST (Mellanox Software Tools) driver set
Loading MST PCI module - Success
Create devices
Unloading MST PCI module (unused) - Success

Change the port type to Ethernet (LINK_TYPE = 2)

# mlxconfig -d /dev/mst/mt4115_pciconf2 set LINK_TYPE_P1=2

Check that the port type was changed to Ethernet

# ibdev2netdev
mlx5_0 port 1 ==> ens1np0 (Down)
mlx5_1 port 1 ==> enp12s0np0 (Down)
mlx5_2 port 1 ==> enp132s0np0 (Up)
mlx5_3 port 1 ==> enp139s0np0 (Down)